other

SCH11-EP Portable Transit-Time Ultrasonic Flowmeter

50-hour battery (rechargeable), 4.3'' color LCD multi-line display all integrated into a rugged, watertight enclosure.

Data logger function.

The heat measurement function by configuring with paired temperature sensors.

♦  Non-invasive transducers.

♦  Wide bi-directional flow range of 0.01 m/s to 12 m/s. Wide liquid temperature range:  -35~200.

Works reliably in both clean and somewhat dirty liquids with turbidity<10000ppm.

Lightweight and easily transportable in box.

  • Item No :

    SCH11-EP
  • Order(MOQ) :

    5
  • Payment :

    T/T
  • Product Origin :

    China

SCH11-EP Portable Transit-Time Ultrasonic Flowmeter

The clamp-on ultrasonic transducers (sensors) are mounted on the external surface of the pipe for non-invasive and non-intrusive flow measurement of liquid and liquefied gasses in fully filled pipe. Two pairs of transducers are sufficient to cover the most common pipe diameter ranges. In addition, its optional thermal energy measurement capability makes it possible to carry out a complete analysis of thermal energy usage in any facility.

This flexible and easy to use flow meter is the ideal tool for the support of service and maintenance activities. It can also be used for the control or even for the temporary replacement of permanently installed meters.

Specifications: Transmitter

Measurement principle Ultrasonic transit-time difference correlation principle
Flow velocity range 0.01 to 12 m/s, bi-directional
Resolution 0.25mm/s
Repeatability 0.2% of reading
Accuracy ±1.0% of reading at rates >0.3 m/s);±0.003 m/s of reading at rates<0.3 m/s
Response time 0.5s
Sensitivity 0.003m/s
Damping of displayed value 0-99s(selectable by user)
Liquid Types Supported both clean and somewhat dirty liquids with turbidity <10000 ppm
Power Supply AC: 85-265V Up to 50 h with fully charged internal batteries
Enclosure type Portable
Degree of protection IP65 according to EN60529
Operating temperature  -20 to +60
Housing material ABS
Display 4.3'' color LCD multi-line display
Units User Configured (English and Metric)
Rate Rate and Velocity Display
Totalized gallons, ft³, barrels, lbs, liters, m³,kg
Thermal energy unit GJKWh can be optional
Communication 4~20mA(accuracy 0.1%),, Relay, RS232, RS485 (Modbus), Logged data, GPRS/GSM
Security Keypad lockout, system lockout
Size 270X215X175mm
Weight 3kgs

 

Specifications: Transducer

Degree of protection IP65 according to EN60529.(IP67 or IP68 Upon request)
Suited Liquid Temperature -35~200 
Pipe diameter range 20-50mm for type B, 40-5000mm for type A
Transducer Size Type B    40(h)*24(w)*22(d)mm
Type A    46(h)*31(w)*28(d)mm
Material of transducer Aluminum + Peek
Cable Length Std:5m
Temperature Sensor Pt1000, 0 to 200, Clamp-on and Insertion type   Accuracy: ±0.1%

 

FAQ

1.Can we accept samples customized?

No problem for samples order, and welcome your testing before your big order.

 

2.OEM and ODM are available?

Yes, we accept customized products

 

3.Can I get a lower price if I order large quantities?

A : Yes, Cheaper prices with bigger size orders, please contact us and we will give you a quatation.

leave a message
For any request of information or technical support, fill in the form. All fields marked with an asterisk* are required.
Submit

Related Products

SCH11-DC Dual-channel clamp on ultrasonic flowmeter
♦  Dual channel non-invasive transducers to ensure high accuracy 0.5% of the flow meter. ♦  Easy to install, cost effective, and require no pipe cutting or processing interrupt. ♦  Wide liquid temperature range: -35℃~200℃. ♦  Data logger function. ♦   Aluminum or Stainless steel SUS304 sensors for your optional. ♦  Thermal energy measurement capability can be optional. ♦  For commonly used pipe materials and diameters from 20mm to 6.0m. ♦   Wide bi-directional flow range of 0.01 m/s to 15 m/s  
View More
SCH11-DI Insertion Dual Channels Ultrasonic Flow Meter
♦Dual channels Insertion transducers to ensure high accuracy 0.5% of the flow meter ♦Hot-tapped installation, no pipe line flow interrupted. ♦No moving parts, no pressure drop, no maintenance. ♦Spool-piece transducer for best accuracy and better long-term stability. ♦High temp. Insertion transducers are suitable for high temperature of -35℃~150℃. ♦Wide bi-directional Flow range of 0.03 to 36 m/s, and wide range of pipe sizes from DN65 to DN6000. ♦Data logger function. ♦The heat measurement function by configuring with paired temperature sensors
View More
SCH11-DP Portable Dual Channels Clamp On Ultrasonic Flow Meters
♦50-hour battery (rechargeable), 4.3'' color LCD mult-line display all integrated into a rugged, watertight enclosure. ♦± 0.5% high accuracy flow measurement. ♦Data logger function. ♦The heat measurement function by configuring with paired temperature sensors. ♦Non-invasive transducers. ♦Wide bi-directional flow range of 0.01 m/s to 12 m/s. Wide liquid temperature range: -35℃~200℃. ♦Works reliably in both clean and somewhat dirty liquids with turbidity<10000ppm. ♦Lightweight and easily transportable in box. ♦With the ability of Dynamic zero.
View More
SCH11-MI Transit-Time Multi-channel Insertion Ultrasonic Flowmeter
♦Works on the multi-channel transit-time principle. The accuracy is 0.5%. ♦Wide bi-directional Flow range of 0.01 m/s to 12 m/s. Repeatability is less than 0.15%. ♦3.6V 76Ah battery power supply,with lifetime over 10 years (measuring cycle: 500ms). ♦Low starting flow, super wide turndown ratio Q3:Q1 as 400:1. ♦With storage function. Can storage both forward flow and back flow  ♦Hot-tapped installation, no pipe line flow interrupted. ♦Standard output is RS485 modbus, Pulse, NB-IoT, 4G, GPRS, GSM can be optional. ♦Two channels and four channels can be optional.
View More
SCH11-EI Transit-Time Insertion Ultrasonic Flowmeter
♦ Hot-tapped installation, no pipe line flow interrupted. ♦ No moving parts, no pressure drop, no maintenance. ♦ Spool-piece transducer for best accuracy and better long-term stability. ♦ High temp. Insertion transducers are suitable for high temperature of -35℃~150℃. ♦ Wide bi-directional Flow range of 0.03 to 36 m/s, and wide range of pipe sizes from DN65 to DN6000. ♦ Data logger function. ♦ The heat measurement function by configuring with paired temperature sensors
View More
SCH11-EP Portable Transit-Time Ultrasonic Flowmeter
♦ 50-hour battery (rechargeable), 4.3'' color LCD multi-line display all integrated into a rugged, watertight enclosure. ♦ Data logger function. ♦ The heat measurement function by configuring with paired temperature sensors. ♦  Non-invasive transducers. ♦  Wide bi-directional flow range of 0.01 m/s to 12 m/s. Wide liquid temperature range:  -35℃~200℃. ♦ Works reliably in both clean and somewhat dirty liquids with turbidity<10000ppm. ♦ Lightweight and easily transportable in box.
View More
SCH11-EH Handheld Transit-Time Ultrasonic Flowmeter
♦14 hours battery (rechargeable), back-lit 4 lines display. ♦Data logger function. ♦Can be used for mobile measurement, flow rate calibration, data comparing, meters running status checking. ♦Non-invasive transducers. ♦Wide bi-directional flow range of 0.01 m/s to 12 m/s. Wide liquid temperature range: -35℃~200℃. ♦Works reliably in both clean and somewhat dirty liquids with turbidity<10000ppm. ♦Lightweight and easily transportable in box.
View More
SCH11-EC Wall-mounted Transit-time Ultrasonic Flowmeter
♦ Non-invasive transducers are easy to install, cost effective, and require no pipe cutting or processing interrupt. ♦ Wide liquid temperature range: -35℃~200℃. ♦  Data logger function. ♦ Thermal energy measurement capability can be optional.      ♦  For commonly used pipe materials and diameters from 20mm to over 6.0m. ♦ Wide bi-directional flow range of 0.01 m/s to 12 m/s.
View More

Need Help? Chat with us

leave a message
For any request of information or technical support, fill in the form. All fields marked with an asterisk* are required.
Submit

Home

Products

whatsApp

contact