other

SCH-JHAS69 Series isolation switch

♦With alloy contacts, electrical special silver long life and highreliability.

♦Small size,space-saving installation.

♦Construct a protective finger to make the operation safe.

♦With a varielyofinstallation,ease of application of variouspurpose(panel mount,rail mount, sealed switch box type).

♦lP66 degree of protection

  • Item No :

    SCH-JHAS69
  • Order(MOQ) :

    5
  • Payment :

    T/T
  • Product Origin :

    China

SCH-JHAS69 Series isolation switch

SCH-JHAS69 isolation switch is widely used in industrial controlmachineryand various electrical appliances, and caneffectively solve the problems of emergency disconnection.safety disconnection,machine control, motor control and soon.

Technical Specification

SCH-JHAS69-PMR-4RY64 / 3RY64

Current 20A 32A 40A 63A 80A
TYPe SCH-JHAS69-PM20R-4RY64 SCH-JHAS69-PM32R-4RYE4 SCH-JHAS69-PMAOR-4RY64 SCH-JHAS69:PMG3R-3RY64 SCH-JHASG9-PMBOR3RY64
Rated carry current 20A 32A 40A 63A 80A
Rated operating  current AC-23A 16A 25A 32A 45A 45A
Rated operating current AC-3 12A 23A 30A 37A 37A
Rated power control
AC-23A
240V 4KW 7.5KW 9KW 15KW 15KW
440V 7.5KW 12.5KW 16KW 22KW 22KW
Rated power control
AC-3
240V 3KW 5.5KW 7.5KW 11KW 11KW
440V 5.5KW 11KW 15KW 18.5KW 18.5KW
UL-CSA
(HP)
Motor load
240V 3KW 5KW 5KW 10KW 10KW
440V 7.5KW 10KW 10KW 20KW 20KW
Rated     short-time
withstand current(Icw)
250A 400A 500A 600A 850A
Connect  wires(mm²) 0.5-10MM 1-16MM
Screw  torque(N·m) 0.8-1.7N·m 1.5-2N·m
Rated insulation voltage 690V

 

SCH-JHAS69-PMR-4B64 / 3B64

Curren 20A 32A 40A 63A 80A
TVDe SCH-JHAS69-PW20R-4B⁶4 SCH-JHAS69PM32R-4864 SCH-JHAS69-PM⁴OR-4B64 SCH-JHAS69-PM⁶3R-3864 SCH-JHASG9-PM8OR-3B64
Rated carry current 20A 32A 40A 63A 80A
Rated operating current
AC-23A
16A 25A 32A 45A 45A
Rated operating  current
AC-3
12A 23A 30A 37A 37A
Rated   power   control
AC-23A
240V 4KW 7.5KW 9KW 15KW 15KW
440V 7.5KW 12.5KW 16KW 22KW 22KW
Rated   power   control
AC-3
240V 3KW 5.5KW 7.5KW 11KW 11KW
440V 5.5KW 11KW 15KW 18.5KW 18.5KW
UL-CSA
Motor  load(HP)
240V 3KW 5KW 5KW 10KW 10KW
440V 7.5KW 10KW 10KW 20KW 20KW
Rated  short-time
withstand  current(Icw)
250A 400A 500A 600A 850A
Connect  wires(mm²) 0.5-10MM² 1-16MM²
Screw  torque(N·m) 0.8-1.7N·m 1.5-2N·m
Rated  insulation  voltage 690V

 

SCH-JHAS69-PM-3/4

Current 20A 32A 40A 63A 8OA
TYPe SCH-JHAS69-PM20-4 SCH-JHAS69-PM324 SCH-JHAS69-PM40-4 SCH-JHAS69-PMG3-3 SCH-JHAS69-PM80-3
Rated carry current 20A 32A 40A 63A 80A
Rated  operating  current
AC-23A
16A 25A 32A 45A 45A
Rated operating current
AC-3
12A 23A 30A 37A 37A
Rated power control
AC-23A
240V 4KW 7.5KW 9KW 15KW 15KW
440V 7.5KW 12.5KW 16KW 22KW 22KW
Rated  power  contro
AC-3
240V 3KW 5.5KW 7.5KW 11KW 11KW
440V 5.5KW 11KW 15KW 18.5KW 18.5KW
UL-CSA
(HP)
Motor   load
240V 3KW 5KW 5KW 10KW 10KW
440V 7.5KW 10KW 10KW 20KW 20KW
Rated short-time
witnstand current(Icw)
250A 400A 500A 600A 850A
Connect wires(mm²) 0.5-10MM 1-16MM²
Screw  torque(N·m) 0.8-1.7N·m 1.5-2N·m
Rated insulation voltage 690v

 

SCH-JHAS69-DCR-4RY64 / 3RY64

Curren 20A 32A 40A 63A 80A
TYpe SCH-JHAS69-DC20R-4RY64 SCH-JHAS69-DC32R-4RYE4 SCH-JHAS69-DC4OR-4RY64 JHAS69-DC63R-3RY64 SCH-JHAS69-DC80R-3RY64
Rated carry current 20A 32A 40A 63A 80A
Rated  operating  current
AC-23A
16A 25A 32A 45A 45A
Rated operating current
AC-3
12A 23A 30A 37A 37A
Rated  power  control
AC-23A
240V 4KW 7.5KW 9KW 15KW 15KW
440V 7.5KW 12.5KW 16KW 22KW 22KW
Rated power control 240V 3KW 5.5KW 7.5KW 11KW 11KW
440V 5.5KW 11KW 15KW 18.5KW 18.5KW
UL-CSA(HP)
Motor load
240V 3KW 5KW 5KW 10KW 10KW
440V 7.5KW 10KW 10KW 20KW 20KW
Rated  short-time
withstand  current(Icw)
250A 400A 500A 600A 850A
Connect  wires(mm²) 0.5-10MM² 1-16MM²
Screw  torque(N·m) 0.8-1.7N·m 1.5-2N·m
Rated  insulation  voltage 690V

 

SCH-JHAS69-DCR-4B64/3B64

Current 20A 32A 40A 63A 8OA
 T Y P e SCH-JHAS69-DC20R-4B64 SCH-JHAS69-DC32R-4B64 SCH-JHAS69-DC40R-4B64 SCH-JHAS69-DC63R-3B64 SCH-JHAS69-DCB0R-3B64
Rated carry current 20A 32A 40A 63A 80A
Rated  operating  current
AC-23A
16A 25A 32A 45A 45A
Rated operating current
AC-3
12A 23A 30A 37A 37A
Rated  power  control
AC-23A
240V 4KW 7.5KW 9KW 15KW 15KW
440V 7.5KW 12.5KW 16KW 22KW 22KW
Rated power control
AC-3
240V 3KW 5.5KW 7.5KW 11KW 11KW
440V 5.5KW 11KW 15KW 18.5KW 18.5KW
UL-CSA(HP)
Motor load
240V 3KW 5KW 5KW 10KW 10KW
440V 7.5KW 10KW 10KW 20KW 20KW
Rated  short-time
withstand  current(Icw)
250A 400A 500A 600A 850A
Connect  wires(mm²) 0.5-10MM 1-16MM
Screw  torque(N·m) 0.8-1.7N·m 1.5-2N·m
Rated  insulation  voltage 690V

 

SCH-JHAS69-DC-4/3

Current 20A 32A 40A 63A 80A
T Y P e SCH-JHAS69-0C20-4 SCH-JHAS69-0C32-4 SCH-JHAS69-DC40-4 SCH-JHAS69-DC63-3 SCHJHAS69-DC80-3
Rated carry current 20A 32A 40A 63A 80A
Rated  operating  current
AC-23A
16A 25A 32A 45A 45A
Rated operating current
AC-3
12A 23A 30A 37A 37A
Rated  power  control
AC-23A
240V 4KW 7.5KW 9KW 15KW 15KW
440V 7.5KW 12.5KW 16KW 22KW 22KW
Rated power control
AC-3
240V 3KW 5.5KW 7.5KW 11KW 11KW
440V 5.5KW 11KW 15KW 18.5KW 18.5KW
UL-CSA(HP)
Motor load
240V 3KW 5KW 5KW 10KW 10KW
440V 7.5KW 10KW 10KW 20KW 20KW
Rated  short-time
withstand  current(Icw)
250A 400A 500A 600A 850A
Connect  wires(mm²) 0.5-10MM² 1-16MM
Screw  torque(N·m) 0.8-1.7N·m 1.5-2N·m
Rated  insulation  voltage 690V

 

SCH-JHAS69-LK-4RY/3RY

Current 20A 32A 40A 63A 80A
T Y P e SCH-JHAS69-LK20-4RY SCH-JHAS69-LK32-4RY SCH-JHAS60-LK40-4RY SCH-JHAS69-LK63-3RY SCH-JHAS69-LKBO-3RY
Rated carry current 20A 32A 40A 63A 80A
Rated  operating  current AC-23A 16A 25A 32A 45A 45A
Rated operating current AC-3 12A 23A 30A 37A 37A
Rated  power  control
AC-23A
240V 4KW 7.5KW 9KW 15KW 15KW
440V 7.5KW 12.5KW 16KW 22KW 22KW
Rated power control
AC-3
240V 3KW 5.5KW 7.5KW 11KW 11KW
440V 5.5KW 11KW 15KW 18.5KW 18.5KW
UL-CSA(HP)
Motor load
240V 3KW 5KW 5KW 10KW 10KW
440V 7.5KW 10KW 10KW 20KW 20KW
Rated  short-time
withstand  current(Icw)
250A 400A 500A 600A 850A
Connect  wires(mm²) 0.5-10MM 1-16MM
Screw  torque(N·m) 0.8-1.7N·m 1.5-2N·m
Rated  insulation  voltage 690V

 

JHAS69-LK-4 / 3

Current 20A 32A 40A 63A 80A
T Y P e  SCH-JHAS69-LK20-4 SCH-JHAS69-LK32-4 SCH-JHAS69-LK4D-4 SCH-JHAS69-LK63-3 SCH-JHAS69-LK80-3
Rated carry current 20A 32A 40A 63A 80A
Rated  operating  current AC-23A 16A 25A 32A 45A 45A
Rated operating current AC-3 12A 23A 30A 37A 37A
Rated  power  control
AC-23A
240V 4KW 7.5KW 9KW 15KW 15KW
440V 7.5KW 12.5KW 16KW 22KW 22KW
Rated power control
AC-3
240V 3KW 5.5KW 7.5KW 11KW 11KW
440V 5.5KW 11KW 15KW 18.5KW 18.5KW
UL-CSA(HP)
Motor load
240V 3KW 5KW 5KW 10KW 10KW
440V 7.5KW 10KW 10KW 20KW 20KW
Rated  short-time
withstand  current(Icw)
250A 400A 500A 600A 850A
Connect  wires(mm²) 0.5-10MM² 1-16MM
Screw  torque(N·m) 0.8-1.7N·m 1.5-2N·m
Rated  insulation  voltage 690V

 

SCH-JHAS69-EL-4/3

Current 20A 32A 40A 63A 8OA
T Y P e SCH-JHAS69-EL20R4 SCH-JHAS69-EL32R-4 SCH-JHAS69-EL40R-4 SCH-JHAS69-EL63R-3 SCH-JHAS69-EL8OR-3
Rated carry current 20A 32A 40A 63A 80A
Rated  operating  current
AC-23A
16A 25A 32A 45A 45A
Rated operating current
AC-3
12A 23A 30A 37A 37A
Rated  power  control
AC-23A
240V 4KW 7.5KW 9KW 15KW 15KW
440V 7.5KW 12.5KW 16KW 22KW 22KW
Rated power control
AC-3
240V 3KW 5.5KW 7.5KW 11KW 11KW
440V 5.5KW 11KW 15KW 18.5KW 18.5KW
UL-CSA(HP)
Motor load
240V 3KW 5KW 5KW 10KW 10KW
440V 7.5KW 10KW 10KW 20KW 20KW
Rated  short-time
withstand  current(Icw)
250A 400A 500A 600A 850A
Connect  wires(mm²) 0.5-10MM 1-16MM²
Screw  torque(N·m) 0.8-1.7N·m 1.5-2N·m
Rated  insulation  voltage 690V

 

Reference Dimension

JHAS69-PM32R-4RYE4

JHAS69-PM32R-4864

JHAS69-PM32-4

JHAS69-0C32R-4RYE4

JHAS69-0C32R-BE4

JHAS69-0C32-4

JHAS69-LK32-4RY

  JHAS69LK32-4

JHAS69-EL32R-4

JHAS⁶9-EL40R-4

FAQ

Can you produce according to the samples or drawings?

Yes, we can produce by your samples or technical drawings. We can build the molds and fixtures.

 

What is the lead time?

For standard models, lead time is about 3~5 days after order confirmed and payment received.

For OEM orders, the delivery is about 2~3 weeks after data confirmed and payment received.

 

How to solve the quality problems after sales?

Take photos or videos of the problems and send to us.

We will make a satisfied solution for you within 24 hours after we confirm the problems.

leave a message
For any request of information or technical support, fill in the form. All fields marked with an asterisk* are required.
Submit

Related Products

SCH-LDR series power supply
♦AC input range selectable by switch ♦Buit-in EMI filter ♦Protections: Short circuit / Ooverload / Over voltage / Over temperature ♦Cooling by free air convection ♦Can be installed on DIN rail TS-35/7.5 or 15 ♦UL 508(industrial control equipment) listed ♦100% full load burn-in test
View More
SCH-H Series Switching Power Supply
●Low price and high reliability ●105℃ Output capacitor ●AC input power suitable for the world ●High efficiency and low operation temperature ●Soft-star current can reduce the AC input impact effecticly ●With short-circuit and overload protection ●Compact size,light weight ●100% full-load burn-in test ●Installed with EMI filter,minimum wave
View More
SCH-JHAS69 Series isolation switch
♦With alloy contacts, electrical special silver long life and highreliability. ♦Small size,space-saving installation. ♦Construct a protective finger to make the operation safe. ♦With a varielyofinstallation,ease of application of variouspurpose(panel mount,rail mount, sealed switch box type). ♦lP66 degree of protection
View More
SCH-JHAS80 series Panel Mount Isolating Switch
♦Installation Options: Screw Installation, Rail Installation or Door Installation ♦Can padlock, more safely and reliable, diameter of lock is Ø4-Ø5mm ♦Standard: EN60947-3 and GB14048.3. ♦Degree of Protection: IP20 or IP67(with Plastic or Aluminium enclosures).
View More

Need Help? Chat with us

leave a message
For any request of information or technical support, fill in the form. All fields marked with an asterisk* are required.
Submit

Home

Products

whatsApp

contact