Frequency Inverter

SCH600 Smart inverter

SCH600 Smart inverterSCH600 is our newest compact inverter. It is designed as easy installation, user-friendly interface, DIN rail mounting, and simple operation.Technical SpecificationsTable2-2Techni

SCH600 Smart inverter

SCH600 is our newest compact inverter. It is designed as easy installation, user-friendly interface, DIN rail mounting, and simple operation.

Technical Specifications

Table2-2Technical Specifications for E600 Series Inverters 

 


ItemsContents
InputRated Voltage Range3-phase 380-480V(+10%,-15%)tc l
1-phase 220-240V±15%
Rated Frequency50/60Hz,Frequency ±5%
OutputRated Voltage Range3-phase 0-INPUT (V)
Frequency Range0.50~650.0Hz
Control
Mode
Carrier Frequency08-6K;Mfr's vale:3K
Input Frequency ResolutionDigital setting:0.01Hz,analog setting:max frequency*0.2%
Control ModeInduction motor:VVVF
Start Torque1HZ100%
Overload Capacity150%rated current,60 seconds
Torque ElevatingManual Torque Promotion includes 1-20 curves.

V/F Curve3 kinds of modes:beeline type,n-th power type(1.5 th
power,1.8      th     power,1.9th     power,square)and
under-defined VVVF curve.
Startup modeStart directly
DC BrakingDC braking frequency:0.20-50.00 Hz,
braking time:0.00~30.00s
Jogging ControlJogging frequency range:min frequency~max frequency
jogging acceleration/deceleration time:0.1~3000s
Auto Circulating Running and
multi-stage speed running
Terminals control can realize 15-stage speed running
Built-in PID adjustingEasy to realize a system for process closed-loop control
Auto voltage regulation (AVR)When source voltage changes,the modulation rate can be
adjusted automatically,so that the output voltage is
unchanged.
Operation
Function
Frequency SettingPotentiometer or external analog signal (0~5V,0~10V,
0~20mA,4~20mA);keypad (▲/V keys,terminal
external control logic and PC/PLC)
Start/Stop ControTerminal control,keypad control or communication control
Running Command Channels3 kinds of channels from keypad panel,control terminal and
MODBUS
Frequency SourceFrequency sources:given digit,given analog voltage,given
analog current and given MODBUS
Accessorial frequency Source0:Memory of digital given
1:External analog All
3:Stage speed adjusting
4:PID adjusting
OptionalBuilt-in EMI filter,built-in braking unit
Protection
  Function
nput under-voltage,DC over-voltage,over-current,inverter over-load,motor over-load,over
heat,analog disconnected protection,etc
DisplayOutput frequency,rotate-speed (rpm),output current,output voltage,DC-link voltage,PID
feedback,PID setpoint,types of fault,and parameters setting
LED indicators showing the working status of inverter
Fnvironment
  Conditions
Equipment LocationIn an indoor location,Prevent exposure from direct
sunlight,Free from dust,tangy caustic gases,flammable
gases,steam or the salt-contented,etc
Environment Temperature-10℃~+40℃
Environment HumidityBelow 90%(no water-bead coagulation)
Vibration StrengthBelow 0.5g(acceleration)
Height above sea level1000m or below
Protection
   level
IP20
Applicable
   Motor
0.4~22kW

 

Product appearance

The external structure of SCH600 series inverter isplastic housings. Wall hanging type isadopted. Good poly-carbon materials are adopted through die-stamping for plastichousing with nice form, good strength and toughness.Taking SCH600-0030T3for instance, the external appearance and structure are shown as inbelow Fig.

 

E600 Series Appearance

E600 interface introduction

Structure No. Content
Q1/Q2 structure1
18-core net cable remote keypad interface
2RS-485 communication (A+,B-)

 

Panel Illustration

 E600 Series Panel Illustration

E600 Series  LED remote keypad

E600 Series  Single line of LCD keypad

Note:Local panels cannot be pulled out.Please select AAor A6 control panel to realize remote control, which isconnected by 8-core telephone cable. 

Table 3-3    Uses of Keys

KeysNamesRemarks
FunFunTo call function code and switch over display mode
SetSetTo call and save data.
▲UpTo increase data(speed control or setting parameters)
▼DownTo decrease data (speed control or setting parameters
RunRunTo start inverter
Stop/resetStop or resetTo stop inverter;to reset in fault status;to change function codes in a code
group or between two code groups.

 

Parameters Setting

This inverter has numerous function parameters, which the user can modify to effect different modes ofoperation control. User needs to realize that if user sets password valid (F107=1), user‘s password must beentered first if parameters are to be set after power off or protection is effected, i.e., to call F100 as per themode in Table 3-4 and enter the correct code. User‘s password is invalid before delivery, and user could setcorresponding parameters without entering password.

E600 Series Steps for Parameters Setting

E600 Series plan

Note:

1. Please only connect power terminals L1/R and L2/S with power grid for single-phase inverters.

2. 485 communication port has built-in standard MODBUS communication protocol. Communication port is on therightside of inverter.

3. The contact capacity is 10A/125VAC. NO/NC: 3A 250VAC/30VDC.

FAQ

Can I get some samples?

Yes, Sample order is available for quality check and market test. But you have to pay the express cost.

 

What's delivery time?

It usually takes about 3-5 working days for small order and 10-15 days for big order.

 

How to solve the quality problems after sales?

Take photos or videos of the problems and send to us.

We will make a satisfied solution for you within 24 hours after we confirm the problems.